EEG Signal Processing and Machine Learning. Saeid Sanei
Читать онлайн книгу.It is based on a Bayesian GMM applied at each location of a time–frequency map of the EEGs.
3.5 Electronic Models
These models describe the cell as an independent unit. The well established models such as the Hodgkin–Huxley model have been implemented using electronic circuits. Although, for accurate models large numbers of components are required, in practise it has been shown that a good approximation of such models can be achieved using simple circuits [56].
3.5.1 Models Describing the Function of the Membrane
Most of the models describing the excitation mechanism of the membrane are electronic realizations of the theoretical membrane model of Hodgkin and Huxley. In the following sections, two of these realizations are discussed.
Figure 3.14 The Lewis membrane model [57].
3.5.1.1 Lewis Membrane Model
Lewis electronic membrane models are based on the Hodgkin–Huxley equations. All the components are parallel circuits connected between nodes representing the inside and outside of the membrane. He realized the sodium and potassium conductances using electronic hardware in the form of active filters. Since the model output is the transmembrane voltage V m, the potassium current can be evaluated by multiplying the voltage corresponding to G K by (V m − V K). Figure 3.14 is consequently an accurate physical analogue to the Hodgkin–Huxley expressions, and the behaviour of the output voltage V m corresponds to that predicted by the Hodgkin–Huxley equations. The electronic circuits in the Lewis neuromime had provision for inserting (and varying) not only such constants as G K max, G Na max, V K, V Na, V Cl, which enter the Hodgkin–Huxley formulation, but also τh , τm , τn , which allow modifications from the Hodgkin–Huxley equations. In this realization the voltages of the biological membrane are multiplied by 100 to fit the electronic circuit. In other quantities, the original values of the biological membrane have been used.
3.5.1.2 Roy Membrane Model
As in Figure 3.15, Roy also introduced a model based on the Hodgkin–Huxley model [58]. He used field‐effect transistors (FETs) to simulate the sodium and potassium conductances in the membrane model [58].
In the Roy model the conductance is controlled by a circuit including an operational amplifier, capacitors, and resistors. This circuit is designed to make the conductance behave according to the Hodgkin–Huxley model. Roy's main goal was to achieve a very simple model rather than to simulate accurately the Hodgkin–Huxley model.
3.5.2 Models Describing the Function of a Neuron
3.5.2.1 Lewis Neuron Model
The Lewis model is based on the Hodgkin–Huxley membrane model and the theories of Eccles on synaptic transmission [59]. The model circuit is illustrated in Figure 3.16. This neuron model is divided into two sections: the synaptic section and the section generating the action pulse. Both sections consist of parallel circuits connected to the nodes representing the intracellular and extracellular sites of the membrane.
Figure 3.15 Circuits simulating (a) potassium and (b) sodium conductances in the Roy membrane model [58].
Figure 3.16 The Lewis neuron model from 1968 [57].
The section representing the synaptic junction is divided into two components: the inhibitory junction and the excitatory junction. The sensitivity of the section generating the action pulse to a stimulus introduced at the excitatory synaptic junction is reduced by the voltage introduced at the inhibitory junction. The section generating the action pulse is based on the Hodgkin–Huxley model which consists of the normal circuits simulating the sodium and potassium conductances, the leakage conductance, and the membrane capacitance. The circuit also includes an amplifier for the output signal. This model may be used in research on neural networks. However, it is actually a simplified version of Lewis's 46‐transistor network having the same form. The purpose of this simplified Lewis model is to simulate the form of the action pulse with moderate accuracy following simple models.
3.5.2.2 The Harmon Neuron Model
The electronic realizations of the Hodgkin–Huxley model are very accurate in simulating the function of a single neuron. However, these circuits are often very complicated. Leon D. Harmon managed to develop a neuron model having a very simple circuit [60]. A circuit of the Harmon neuron model is given in Figure 3.17. The model is equipped with five excitatory inputs which can be adjusted. These include diode circuits representing various synaptic functions. The signal introduced at excitatory inputs charges the 0.02 μF capacitor which, after reaching a voltage of approximately 1.5 V, allows the monostable multivibrator, formed by transistors T1 and T2, to generate the action pulse. This impulse is amplified by transistors T3 and T4. The output of one neuron model may drive the inputs of a large number of the neighbouring neuron models.
Figure 3.17 The Harmon neuron model [60].
Figure 3.18 The Lewis model for simulation of the propagation of the action pulse [57].
3.5.3 A Model Describing the Propagation of the Action Pulse in an Axon
Lewis simulated the propagation of an action pulse in a uniform axon and obtained interesting results [57]. The model structure, illustrated in Figure 3.18, can be seen to include a network of membrane elements as well as axial resistors representing the intracellular resistance. A total of six membrane elements are depicted in the figure. The model is an electronic realization of the linear core‐conductor model with active membrane elements. An approximation of an AP is generated in the output of each membrane element.
3.5.4 Integrated Circuit Realizations
Mahowald et al. [61] used electronic neuron models