is accurate with minimum convergence error compared to GS method. Similarly, the results obtained under varying irradiance and temperature conditions for PV panel such as KD245GX and Shell SP70 using GS and NR techniques are given in Tables 1.4 and 1.5, respectively. It is seen that the parameters such as A, Rse, ILG, Isat increases as there is increase in operating temperature of PV panel. On the flipside, the shunt resistance Rsh decreases with increasing in temperature. Similar observation is found in both the techniques, however the maximum power obtained from NR technique is higher than the GS method.

PV module Estimated parameters at STC
A Rse (Ω) Rsh (Ω) Ilg (A) Isat (A)
KD245GX 1.43 0.156 623.23 8.91 4.71E-07
U5-80 1.606 0.009 68.1 5.21 2.79E-06
Shell SP70 1.553 0.324 321.22 4.7 1.56E-06
PV module Estimated parameters at STC
A Rse (Ω) Rsh (Ω) Ilg (A) Isat (A)
KD245GX 1.429 0.1562 623.235 8.9122 4.67E-07
U5-80 1.6043 0.0086 66.6312 5.2107 2.76E-06
Shell SP70 1.5536 0.3242 321.2234 4.2543 1.42E-06
PV Modules G (W/m2) T(°C) A Rse (Ω) Rsh (Ω) Ilg (A) Isat (A) Vmpp (V) Impp (A) Pmpp (W)
KD245GX 1000 30 1.432 0.157 621.37 8.94 8.39E-07 29.11 8.23 239.61
1000 50 1.45 0.159 614.02 9.05 7.04E-06 26.38 8.21 216.64
1000 70 1.483 0.16 606.84 9.15 4.62E-05 23.68 8.16 193.14
800 25 1.449 0.125 779.04 7.13 5.89E-07 29.69 6.58 195.47
600 25 1.47 0.094 103.87 5.35 7.89E-07 29.34 4.93 144.72
Shell SP70 1000 25 1.553 0.324 321.22 4.7 1.56E-06 16.51 4.25 70.16
800 25 1.577 0.259 401.53 3.76 1.57E-06 16.59